當前位置 : NEB >>> NEB/NEBNext? Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1)/96 reactions/E7416S
NEB/NEBNext? Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1)/96 reactions/E7416S
  • NEB/NEBNext? Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1)/96 reactions/E7416S

NEB/NEBNext? Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1)/96 reactions/E7416S

價格: 試用 市場價: 0.00

貨號: E7416S
品牌: NEB
規(guī)格
數量
庫存(0)
特別 提示
代購產品:無質量問題不接受退換貨,下單前請仔細核對信息。
下單后請及時聯(lián)系客服核對商品價格,訂單生效后再付款。
資深產品顧問
咨詢顧問

全國免費服務熱線

4000-520-616


  • 自營商城 一站式服務
  • 廠家直采 剔除溢價
  • 品質甄選 正品保證
  • 嚴控流程 只做188精品
  • 極速物流 如約送貨
  • 詳情
  • 使用說明
  • 常見問題
    • NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1) are built for more streamlined and informative NGS multiplexing, more accurate determination of transcript abundance, and removal of PCR duplicates. These index adaptors contain a pair of unique dual indices (i5 and i7) and one 11 nt UMI sequence. This set includes 96 unique dual index UMI adaptors, packaged in a single-use 96-well plate with a pierceable foil seal. The universal primer mixis supplied in a separate vial.

      Combining UMI Adaptors with one of the NEBNext RNA library prep kits is simple and straightforward if you follow the protocols found in the UMI Adaptor-specific library prep kit manuals (listed below).

      • NEBNext Ultra II Directional RNA Library Prep Kit for Illumina (NEB #E7760 or NEB #E7765)
      • NEBNext Ultra II RNA Library Prep Kit for Illumina (NEB #E7770 or NEB #E7775)
      • NEBNext rRNA Depletion Kit v2 (Human/Mouse/Rat) (NEB #E7400 or NEB #E7405)
      • NEBNext rRNA Depletion Kit (Bacteria) (NEB #E7850 or NEB #E7860)
      • NEBNext Globin & rRNA Depletion Kit (Human/Mouse/Rat) (NEB #E7750 or NEB #E7755)

      The NEBNext line of Multiplex Oligos can be used with NEBNext sample prep products or other standard Illumina-compatible library preparation protocols. In addition to this set, index adaptors with UMIs are available for PCR-free and standard DNA-seq (NEB #E7395). For multiplexing without UMIs, NEBNext offers several options for added flexibility, including unique dual index primers (NEB #6440,NEB #6442, NEB #E6444, NEB #E6446), dual index primers (NEB #E7600andNEB #E7780), and single primer sets (in 12- and 96-index formats; NEB #E7335,NEB #E7500,NEB #E7710,NEB #E7730,NEB #E6609), as well as an option compatible with EM-seq™ and bisulfite sequencing (NEB #E7140).

      The NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1) workflow shown below details the library barcoding steps of the library preparation process.

      Figure 1: NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1) Workflow
      Figure 2: NEBNext Unique Dual Index UMI Adaptors have equally efficient ligation and subsequent amplification
      A. Universal Human Reference (UHR) RNA (Agilent® #740000) was used to prepare 96 libraries with the NEBNext Ultra II Directional RNA Library Prep Kit (NEB #E7760) following NEBNext Poly(A) mRNA Magnetic Isolation Module (NEB #E7490) enrichment. Library yields were quantified (Agilent Tapestation 4200) and normalized by dividing the individual library yields by the average library yield across all 96 libraries. Adaptor ligation efficiency was robust with uniformity across all 96 Unique Dual Index UMI Adaptors. Each bar represents the average of at least 2 technical replicates.B. NEBNext Unique Dual Index UMI Adaptors have uniform clustering efficiency. 96 libraries were pooled and sequenced on the Illumina NextSeq® 500 (PE70). Each library is expected to contribute 1.04% of the total sequencing reads. Individual library yields were normalized by dividing the number of actual reads by the number of expected reads. No bias was observed across the 96 Unique Dual Index UMI Adaptor libraries.
      Figure 3: NEBNext Unique Dual Index UMI Adaptors outperform competitor UMI adaptors
      Libraries were produced using UHR RNA and the NEBNext Ultra II Directional RNA library prep kit (NEB #E7760) following NEBNext Poly(A) mRNA Magnetic Isolation Module (NEB #E7490) enrichment.A. The average library yield of triplicates is shown for three starting total RNA inputs: 10, 100, and 1,000 ng. During adaptor ligation either NEBNext Unique Dual Index UMI Adaptors or IDT xGen dual index adapters were used. Final library yields were quantified using the Agilent Tapestation 4200.B. Libraries were sequenced on the Illumina NextSeq 500 (PE70). Reads were downsampled to 5 million reads (seqtk) and aligned to the GRCh38 reference genome using HISAT 2.1. UMI information was added using fgbio (AnnotateBamWithUmis) and MarkDuplicates (Picard 2.18.2.1) was used to mark reads with UMI and determine duplication rate. NEBNext Unique Dual Index UMI Adaptor libraries produced libraries with a lower percentage of read duplicates.
      Figure 4: Incorporating UMIs into analysis improves the accurate quantification of duplication rates
      Triplicate libraries of three input amounts (10, 100, and 1000 ng) were produced using UHR RNA and the NEBNext Ultra II Directional RNA Library Prep Kit (NEB #E7760) following NEBNext Poly(A) mRNA Magnetic Isolation Module (NEB #E7490) enrichment and sequenced on the NextSeq 500. Reads were downsampled (seqtk) to 5 million reads and mapped to the GRCh38 reference genome (HISAT 2.1) and Fgbio (AnnotateBamWithUmis) was used to add the UMI information. Two approaches were used to calculate duplication: position and UMI information (green bars) or position alone (yellow bars) using MarkDuplicates (Picard 2.18.2.1).
      Figure 5: Unique Dual Index UMI Adaptors allow for the correction of bias introduced with PCR amplification
      Libraries were produced using UHR RNA and the NEBNext Ultra II Directional RNA Library Prep Kit (NEB #E7760) following NEBNext Poly(A) mRNA Magnetic Isolation Module (NEB #E7490) enrichment. Four technical replicate libraries were produced at three RNA inputs (10, 100 and 1,000 ng). Libraries were sequenced on the NextSeq 500 (PE70) and downsampled (seqtk)to 10 million reads for further analysis. To assess PCR bias, the same sequencing reads were compared using typical transcript abundance analysis (Salmon 0.9.1) against UMI deduplicated reads. UMI deduplication was performed by first mapping to the GRCh38 reference genome (HISAT 2.1) followed by Fgbio to add the UMI information. Non-duplicate reads were randomly ordered and converted to fastq before re-assessing transcript abundance using Salmon (0.9.1). The ratio of UMI-adjusted counts/raw read counts with no deduplication was calculated. Number of transcripts with at least 1 count in any library and with UMI/raw ratio ≥2 are plotted. In total, approximately 90,000 total transcripts were detected. An increased number of PCR cycles in library preparation correlates with the number of transcripts that shift upon UMI correction.
      Figure 6: IGV visual representation of mapped reads adjusted utilizing UMIs in MDM4 (chr1:204,548.089-204,558,681)
      Several isoforms of MDM4 locus showed >2X fold change in UMI/raw ratio in a 10 ng library sequenced on the NextSeq 500 (PE70). Reads that are considered to originate from unique molecules are shown in blue. Duplicate reads determined by UMI sequence and mapped read position (red bars) can be removed to improve accuracy of transcript abundance in downstream analysis.

      This product is related to the following categories:
      NEBNext? Multiplex Oligos (Adaptors & Primers),
      Next Generation Sequencing Library Preparation
    售后保障
    螞蟻淘生物188,秉承螞蟻淘一貫的嚴謹態(tài)度,由螞蟻淘公司專業(yè)人員負責品控、采購、物流、銷售、售后,保障正品優(yōu)質。以“快速好省,為科研提供好產品、好價格”為理念,直接鏈接原廠家,從全國各地原制造商嚴格挑選188款科研精品,剔除品牌溢價,188生物新電商,把好的產品帶給科研!? 力求給你最優(yōu)質的商品。
  • Q:生物188產品正品保障嗎?
    A:生物188質量把控人員具有十年的從業(yè)經驗,在業(yè)界享有良好的口碑;自營商城,直接從廠家采購, 自己的團隊負責國際物流和清關,中間沒有第三方,所有流程嚴格把控,100%保證正品,假一罰十。

    Q:下單后可以修改訂單嗎?
    A:下單后的商品付款之前可以修改;訂單付款成功,需要聯(lián)系我們客服進行修改;客服電話:4000-520-616

    Q:可以開發(fā)票嗎?
    A:本網站所售商品都是正規(guī)清關,均開具16%正規(guī)發(fā)票,發(fā)票金額含配送費金額,另有說明的除外。

    Q:商品幾天可以發(fā)貨?
    A:生物188商品,全部現(xiàn)貨銷售,付款后即可發(fā)貨,一般一周內送達!

    Q:如何聯(lián)系商家?
    A:有任何問題夠可以電話咨詢我們,全國24小時免費服務熱線:4000-520-616 或聯(lián)系我們的在線客服QQ:1570468124

    Q:收到的商品少了/發(fā)錯了怎么辦?
    A:同個訂單購買多個商品可能會分為一個以上包裹發(fā)出,可能不會同時送達,建議查看訂單詳情是否是 部分發(fā)貨狀態(tài);如未收到,可聯(lián)系在線客服或者致電4000-520-616。

    Q:退換貨/維修需要多長時間?
    A:一般情況下,退貨處理周期為客戶收到產品一個月內(以快遞公司顯示簽收時間為準),包裝規(guī)格、 數量、品種不符,外觀毀損、短缺或缺陷,請在收到貨24小時內申請退換貨;特殊商品以合同條款為準。

何為188

極簡而嚴謹,我們僅銷售188款生物醫(yī)學科研用品,款款都是爆款;因為少所以聚焦,聚焦甄選每一款產品,聚焦服務每一位客戶!

關注我們 :

點擊QQ聯(lián)系我們
生物188微信

關注188微信公眾號

獲取最新優(yōu)惠活動通知
  • 品質甄選,正品保證

  • 自營電商,廠家直采

  • 極簡主義,188精品